Product Categories
We currently have the following Product Ranges available for Reinforcement
Reinforcing Bar
| Code |
Reinforcing bar to bs 4449 and cut and bent to BS8666:2000, supplied in high yield grade 460n/mm2 and plaind round to grade 250n/mm2.
All other shapes are shape code 99 and require a fully dimensional sketch.
Click here to view the full-size cut and bent chart
| Size | 8mm | 10mm | 12mm | 16mm | 20mm | 25mm | 32mm | 40mm |
| Kg/m 12m/tonne | 0.22 211 | 0.395 135 | 0.888 94 | 1.579 53 | 2.466 | 3.854 22 | 6.313 13 | 9.864 8 |
Standard fabric
| Code |
Manufactured to BS 4483 from cold reduced wire which complies with BS 4482. Each wire intersection is resistance welded using electronically controlled techniques.
Standard sheet size: 4.8m x 2.4m
Merchant sheet size: 3.6m x 2.0m
| Standard sizes (4,800 x 2,400) | |||||||||||
BS ref. | Mesh size normal pitch of wires | Wire sizes | Cross sectional area per meter width | Normal weight per m2 (kg) | Sheets per tonne (approx) | Sheet weight (kg) | Sheets per bundle | Sq. metres per tonne | |||
Main (mm) | Cross (mm) | Main (mm) | Cross (mm) | Main (mm) | Cross (mm) | ||||||
A393 B1131 C785 D98 | 200 100 100 200 | 200 200 400 200 | 10 12 10 5 | 10 8 6 5 | 393 1131 785 98.0 | 393 252 70.8 98.0 | 6.16 10.90 6.72 1.54 | 15 8 13 57 | 70.96 125.57 77.41 17.74 | 18 10 16 60 | 162.34 91.74 148.81 649.35 |
| Standard sizes (3,600 x 2,000) | |||||||||||
BS ref. | Mesh size normal pitch of wires | Wire sizes | Cross sectional area per meter width | Normal weight per m2 (kg) | Sheets per tonne (approx) | Sheet weight (kg) | Sheets per bundle | Sq. metres per tonne | |||
Main (mm) | Cross (mm) | Main (mm) | Cross (mm) | Main (mm) | Cross (mm) | ||||||
A393 A252 A193 A142 | 200 200 200 200 | 200 200 200 200 | 10 8 7 6 | 10 8 7 6 | 393 252 193 142 | 393 252 193 142 | 6.16 3.95 3.02 2.22 | 23 35 46 63 | 44.35 28.44 21.74 15.98 | 26 30 50 50 | 162.34 253.16 331.13 450.45 |
Halfen HBM couplers
| Code |
The HBM system consists of high-strength couplers factory-swaged onto grade 500 high-yield reinforcement bars. Anchorage reinforcement (female socket bars) can be supplied in shapes and lengths to suit almost any application configuration. The male connection bar has a hot-forged ‘upset’ end onto which is rolled a standard metric thread.
HBM is hallmarked by off-the-shelf availability and CARES Technical Approval.
Formrib permanent shuttering
| Code | Description |
| FORMRIB/3 | 3m x 0.445m |
A galvanised expanded metal used widely in the construction industry as a permanent shuttering for stopends. It is manufactured from hot-dipped zinc coated steel sheet to BS EN 10142 1991. Sheet size: 3m x 0.445m
MBT couplers
| Code | To Suit Rebar |
| MBT10 | T10 |
| MBT12 | T12 |
| MBT16 | T16 |
| MBT20 | T20 |
| MBT32 | T32 |
| MBT40 | T40 |
The MBT range of couplers provides a cost effective method of joining reinforcing bars particularly when the fixed bar is already in place. They can be installed without any preparation to the bar ends and without any need to rotate bars.
| Bar diameter | 10mm | 12mm | 16mm | 20mm | 25mm | 32mm | 40mm |
| External diameter (d) | 33.4 | 33.4 | 42.2 | 48.3 | 54 | 71 | 81 |
| Total length (l) | 100 | 140 | 160 | 204 | 258 | 312 | 484 |
| Socket size A/F (ins) | 1/2 | 1/2 | 1/2 | 1/2 | 5/8 | 5/8 | 3/4 |
| No. of bolts | 4 | 6 | 6 | 8 | 8 | 10 | 14 |
| Approx. weight (kg) | 0.52 | 0.72 | 1.25 | 1.96 | 3 | 6.5 | 11.3 |
Halfen HIT Insulated Balcony Connection System
| Code |
To facilitate selection and use, a specially-written software programme that calculates shear stress and reinforcement requirements is available.
The HIT System is the latest development in thermal break and reinforcement continuity for cantilevered balcony construction. HIT helps to eliminate the effects of cold bridging (i.e. condensation and mould growth) experienced with reinforcement that is traditionally continuous from internal slab straight through to external balcony.
The HIT System comprises special stainless steel swaged couplings in the tension zone (into which is factory-fitted normal high-yield reinforcement) and stainless steel double-headed studs in the compression zone. These stainless steel components are housed in a high-density polystyrene fabrication which provides the thermal separation between floor slab and balcony.
The HIT System is supplied in versions for in-situ and precast applications and modules of 1.0m and 0.2 metres that can be used in combination to avoid cutting.
Halfen HDB Punching Shear Reinforcement
| Code |
Halfen HDB punching shear reinforcement is designed to prevent punching failure at column heads in concrete flat slab construction – without the traditional need for downstand beams, mushroom-headed columns and thickened floors.
The system is manufactured from ribbed bars which are hot-forged to make double-ended studs (connected by spacer rails) to provide virtually slip-free shear head reinforcement with excellent anchorage. The two or three-stud elements are simply dropped into place in the reinforcing cage and retained in position by means of clip bars and/or tying wire. This typically reduces site installation time from hours to minutes per column head compared
to traditional bent reinforcement.